Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
1.
Am J Crit Care ; 33(2): 145-148, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38424013

RESUMO

BACKGROUND: Recent data indicate that end-of-life management for patients affected by acute decompensated heart failure in cardiac intensive care units is aggressive, with late or no engagement of palliative care teams. OBJECTIVE: To assess current palliative care and end-of-life practices in a contemporary Italian multicenter registry of patients with cardiogenic shock due to acute decompensated heart failure. METHODS: A survey-based approach was used to collect data on palliative care and end-of-life management practices. The AltShock-2 registry enrolled patients with cardiogenic shock from 12 participating centers. A subset of 153 patients with cardiogenic shock due to acute decompensated heart failure enrolled between March 2020 and March 2023 was analyzed, with a focus on early engagement of palliative care teams and deactivation of implantable cardioverter-defibrillators (ICDs). RESULTS: "Do not resuscitate" orders were documented in patient records in only 5 of 12 centers (42%). Palliative care teams were engaged for 21 of 153 enrolled patients (13.7%). Among the 51 patients with ICDs, 6 of 17 patients who died (35%) had defibrillator deactivation. Of the 17 patients who died, 13 died in the hospital and 4 died within 6 months after discharge; 1 patient had ICD deactivation supported by palliative care services at home. CONCLUSIONS: Therapy-limiting practices, including ICD deactivation, are not routine in the Italian centers participating in this study. The results emphasize the importance of integrating palliative care as a simultaneous process with intensive care to address the unmet needs of these patients and their families.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Assistência Terminal , Humanos , Cuidados Paliativos , Assistência Terminal/métodos , Choque Cardiogênico , Morte , Insuficiência Cardíaca/terapia , Unidades de Terapia Intensiva , Itália
2.
Artigo em Inglês | MEDLINE | ID: mdl-37689237

RESUMO

OBJECTIVES: The Durable Mechanical Circulatory Support System After Extracorporeal Life Support registry is a multicenter registry of patients who were bridged from extracorporeal life support to a durable mechanical circulatory support system. Although numerous studies have highlighted the favorable outcomes after implantation of the HeartMate 3 (Abbott), the objective of our study is to examine the outcomes of patients who received HeartMate 3 support after extracorporeal life support. METHODS: Data of patients undergoing HeartMate 3 implantation from January 2016 to April 2022 at 14 centers were collected and evaluated. Inclusion criteria were patients with extracorporeal life support before HeartMate 3 implantation. The outcome was reported and compared with patients receiving other types of pumps. RESULTS: A total of 337 patients were bridged to durable mechanical circulatory support system after extracorporeal life support in the study period. Of those patients, 140 were supported with the HeartMate 3. The other types of pumps included 170 HeartWare HVADs (Medtronic) (86%), 14 HeartMate II devices (7%), and 13 (7%) other pumps (7%). Major postoperative complications included right heart failure requiring temporary right ventricular assist device in 60 patients (47%). Significantly lower postoperative stroke (16% vs 28%, P = .01) and pump thrombosis (3% vs 8%, P = .02) rates were observed in the patients receiving the HeartMate 3. The 30-day, 1-year, and 3-year survivals in patients receiving the HeartMate 3 were 87%, 73%, and 65%, respectively. CONCLUSIONS: In this critically ill patient population, the survivals of patients who were transitioned to the HeartMate 3 are deemed acceptable and superior to those observed when extracorporeal life support was bridged to other types of durable mechanical circulatory support systems.

3.
J Clin Med ; 12(10)2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37240576

RESUMO

Complex ascending and aortic arch surgery requires the implementation of different cerebral protection strategies to avoid or limit the probability of intraoperative brain damage during circulatory arrest. The etiology of the damage is multifactorial, involving cerebral embolism, hypoperfusion, hypoxia and inflammatory response. These protective strategies include the use of deep or moderate hypothermia to reduce the cerebral oxygen consumption, allowing the toleration of a variable period of absence of cerebral blood flow, and the use of different cerebral perfusion techniques, both anterograde and retrograde, on top of hypothermia, to avoid any period of intraoperative brain ischemia. In this narrative review, the pathophysiology of cerebral damage during aortic surgery is described. The different options for brain protection, including hypothermia, anterograde or retrograde cerebral perfusion, are also analyzed, with a critical review of the advantages and limitations under a technical point of view. Finally, the current systems of intraoperative brain monitoring are also discussed.

4.
J Clin Med ; 11(19)2022 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-36233784

RESUMO

When axillary/subclavian arteries are not suitable because of size or anatomy, alternative access for the Impella pump 5.0/5.5 via the innominate artery allows circulatory support and eventually de-escalation from VA-ECMO to isolated left-side support. Moreover, less invasive surgery without the need to open the pericardium reduces the risk of RV dysfunction and bleeding. Finally, upper body strategies allow early rehabilitation during support, which is associated with improved survival in cardiogenic shock.

5.
J Cardiovasc Med (Hagerstown) ; 23(8): 505-512, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35904996

RESUMO

BACKGROUND: Chronic heart valve regurgitation induces left ventricular (LV) volume overload, leading to the development of hypertrophy and progressive dilatation of the ventricle to maintain physiological cardiac output. In order to prevent potential irreversible LV structural changes, the identification of the best timing for treatment is pivotal. OBJECTIVE: To assess the presence and extent of fibrosis in myocardial tissue in asymptomatic patients with valvular heart disease (VHD) and preserved LV dimensions and function undergoing cardiac surgery. METHODS: Thirty-nine patients were enrolled. Sixteen patients were affected by aortic or mitral regurgitation: they were all asymptomatic, undergoing valve surgery according to VHD European Society of Cardiology guidelines. Twenty-three patients with end-stage nonischemic dilated cardiomyopathy (DCM) and severe LV dysfunction undergoing cardiac surgery for implantation of a durable left ventricular assist device (LVAD) served as controls. During surgery, VHD patients underwent three myocardial biopsies at the level of the septum, the lateral wall and LV apex, while in LVAD patients the coring of the apex of the LV was used. For both groups, the tissue samples were analyzed on one section corresponding to the apical area. All slides were stained with hematoxylin and eosin and Masson's trichrome staining and further digitalized. The degree of fibrosis was then calculated as a percentage of the total area. RESULTS: Of 39 patients, 23 met the inclusion criteria: 12 had mitral or aortic insufficiency with a preserved ejection fraction and 11 had idiopathic dilated cardiomyopathy. Quantitative analysis of apical sections revealed a myocardial fibrosis amount of 10 ±â€Š6% in VHD patients, while in LVAD patients the mean apical myocardial fibrosis rate was 38 ±â€Š9%. In VHD patients, fibrosis was also present in the lateral wall (9 ±â€Š4%) and in the septum (9 ±â€Š6%). CONCLUSION: Our case series study highlights the presence of tissue remodeling with fibrosis in asymptomatic patients with VHD and preserved LV function. According to our results, myocardial fibrosis is present at an early stage of the disease, well before developing detectable LV dysfunction and symptoms. Since the relationship between the progressive magnitude of myocardial fibrosis and potential prognostic implications are not yet defined, further studies on this topic are warranted.


Assuntos
Insuficiência da Valva Aórtica , Cardiomiopatias , Cardiomiopatia Dilatada , Doenças das Valvas Cardíacas , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/cirurgia , Fibrose , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/patologia , Função Ventricular Esquerda
6.
J Thorac Cardiovasc Surg ; 164(4): 1120-1137.e2, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35624053

RESUMO

OBJECTIVES: Six months after withdrawal of the HeartWare HVAD System (HVAD; Medtronic) from sale, approximately 4000 patients continue ongoing support with this device. In light of the diminishing experience, this global consensus document summarizes key management recommendations. METHODS: International experts with experience in the management of patients with ongoing HVAD support were invited to summarize key aspects of patient and pump management and highlight differences in the current HeartMate 3 (Abbott Laboratories) ventricular assist device. Clinicians from high-implanting HVAD sites reviewed current literature and reported experience to generate a consensus statement. RESULTS: Specific guidelines to assist in the management of ongoing HVAD patients are developed. Key management protocols and helpful techniques developed from experienced clinicians are combined into a short guideline document. As experience with HeartMate 3 increases, key differences in approach to management are highlighted, where appropriate. CONCLUSIONS: With decreasing worldwide experience in the ongoing management of HVAD-supported patients, this consensus guideline provides a summary of best practice techniques from international centers. Differences in HeartMate 3 management are highlighted.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Estudos Retrospectivos
7.
Future Cardiol ; 18(4): 285-298, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35187952

RESUMO

Right ventricular failure has a high morbidity and mortality in patients suffering from advanced heart failure, pulmonary hypertension, acute myocardial infarction after cardiac surgery and in left ventricular assist device patients. The Impella RP® catheter is a mechanical circulatory device, positioned from a venous femoral percutaneous access and passing through the tricuspid and pulmonary valves, reaches the pulmonary artery. Impella RP (Abiomed Inc., MA, USA) acts as a direct right ventricle bypass and it provides a flow up to 4.4 liters per minute, unloading the right ventricle. The main contraindications are: thrombi in the vena cava, right atrium and ventricle and pulmonary artery; mechanical tricuspid or pulmonary prostheses. In this review, the principles of operations, clinical applications and results of Impella RP are summarized and evaluated.


Right ventricular failure is a severe medical condition characterized by a sudden or a progressive reduction of the function of the right heart. This condition, if left untretated, leads to low blood pressure, reduced oxygen supply to other organs as brain, liver and kidneys, and eventually death. The right ventricular failure can be the consequence of a heart attack or a progressive disease of the heart, such as chronic heart failure, inflammatory diseases or inherited conditions. When medical therapy fails, the function of the right ventricle (RV) can be temporarily replaced by a mechanical device. Impella RP® is a mechanical device, inserted into the heart without the need of a surgical operation, that bypasses the RV and ensures an adequate blood flow. Impella RP, while replaces the right ventricular function, allows time for the right ventricular recovery. When and if the RV recovers, Impella RP can be removed. As all the medical devices, Impella RP can be associated to adverse effects, mainly bleeding and damage of cardiac structures.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Infarto do Miocárdio , Ventrículos do Coração , Humanos , Resultado do Tratamento
8.
J Cardiothorac Vasc Anesth ; 36(4): 1073-1080, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34629238

RESUMO

OBJECTIVES: Right ventricular (RV) dysfunction is a significant cause of morbidity and mortality after cardiac surgery. Minimally invasive mitral valve surgery (MIMVS) increasingly is being performed. The authors aim was to evaluate postoperative RV function in patients who underwent MIMVS versus traditional mitral valve surgery. DESIGN: Six hundred seventy-five patients who underwent elective isolated mitral valve surgery at Centro Cardiologico Monzino from January 2016 to December 2019 were analyzed. After 1:1 propensity score matching, 60 patients were identified in the MIMVS (study group A) and 58 patients in the median sternotomy (control group B) and compared. SETTING: A university-affiliated scientific institute, monocentric. PARTICIPANTS: Patients. INTERVENTIONS: Mitral valve surgery. MEASUREMENTS AND MAIN RESULTS: No in-hospital deaths occurred. Aortic cross-clamp time (102 [87.5-119] v 83 [61-109] minutes, p = 0.0001), cardiopulmonary bypass duration (161.5 [142.5-181] v 105.5 [74-134] minutes, p < 0.0001) and intensive care unit stay (47 [44-72] v 45 [40-47] hours, p = 0.0015) were significantly longer in group A. The tricuspid annular plane systolic excursion was not different between group A and group B neither postoperatively (15 ± 3 v 14 ± 4 mm, p = 0.1) nor at three-month follow-up (18 ± 4 v 15 ± 3 mm, p = 0.3). No differences in peak postoperative lactates, inotropic score, central venous pressure, and pulmonary artery pulsatility index were observed. The length of hospital stay was significantly shorter in the minimally invasive group (ten [eight-13] v 12 [ten-17], p = 0.006). CONCLUSION: The authors study showed that the surgical strategy had no significant impact on postoperative RV function after mitral valve surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Tempo de Internação , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Esternotomia/efeitos adversos , Resultado do Tratamento , Função Ventricular Direita
9.
Eur J Cardiothorac Surg ; 62(1)2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-34718493

RESUMO

OBJECTIVES: To evaluate the competing pro-haemorrhagic contribution of acquired von Willebrand (vW) disease and antithrombotic therapy in patients implanted with continuous-flow left ventricular assist devices (LVADs). METHODS: We compared the extent of vW factor (vWf) degradation [vWf antigen (vWf:Ag)] and a decrease of functional activity of large vWf multimers [vWf collagen binding (vWf:CB)] in LVAD patients who did and did not suffer from bleeding. Data were measured pre-implant, at short-term (t1: <3 months) and long-term (t2: >12 months) follow-up. The occurrence of primary bleeding events, as well as bleeding recurrence, was correlated with patient-specific vWf profile and antithrombotic regimen. Indeed, patients were discharged on warfarin (international normalized ratio: 2-2.5) and aspirin, with the latter withhold after a first bleeding episode. RESULTS: Fifty-three patients were enrolled. The median follow-up was 324 (226-468) days. We recorded 25 primary bleeding events (47% of patients). All primary events occurred in patients on warfarin and aspirin. Both vWf:Ag and vWf:CB decreased significantly post-implant (P = 0.0003 and P < 0.0001), and patients showing pathological vWf:CB/vWf:Ag ratio (<0.7) increased progressively over the time of support (pre-implant = 26%, t1 = 58%, t2 = 74%; P < 0.0001). Of note, activity of large vWf multimers of bleeders was significantly lower at t2 with respect to non-bleeders (vWf:CB: 61 (36-115) vs 100 (68-121), P = 0.04; vWf:CB/vWf:Ag ratio: 0.36 (0.26-0.61) vs 0.58 (0.33-0.96), P = 0.04). Despite these marked differences in the vWf profile, following aspirin discontinuation only 3 patients had bleeding recurrence. CONCLUSIONS: Aspirin contributes significantly to haemorrhagic events in the background of acquired vW disease; its discontinuation significantly reduces bleeding recurrence. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT03255928; ClinicalTrials.gov Identifier: NCT03255928.


Assuntos
Coração Auxiliar , Hemorragia , Aspirina/efeitos adversos , Fibrinolíticos/efeitos adversos , Coração Auxiliar/efeitos adversos , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Hemorragia/prevenção & controle , Humanos , Varfarina/efeitos adversos , Doenças de von Willebrand/etiologia , Fator de von Willebrand/metabolismo
10.
Interact Cardiovasc Thorac Surg ; 34(4): 676-682, 2022 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-34788423

RESUMO

OBJECTIVES: Implanting a durable left ventricular assist device (LVAD) in a patient on extracorporeal life support (ECLS) is challenging. The goal of this study was to compare the results of patients from a European registry who had a durable LVAD implanted with or without transition from ECLS to cardiopulmonary bypass (CPB). METHODS: A total of 531 patients on ECLS support who had an LVAD implant between January 2010 and August 2018 were analysed; after 1:1 propensity score matching, we identified and compared 175 patients in each group. RESULTS: The duration of preoperative ECLS was 7 [standard deviation (SD) 6] vs 7 (SD 6) days in patients with or without CPB (P = 0.984). The surgical time was longer in the CPB group [285 (SD 72) vs 209 [SD 75] min; P ≤ 0.001). The postoperative chest tube output was comparable [1513 (SD 1311) vs 1390 (SD 1121) ml; P = 0.3]. However, re-exploration for bleeding was necessary in 41% vs 29% of patients with or without CPB (P = 0.01) and a significantly higher number of packed red blood cells and fresh frozen plasma [8 (SD 8) vs 6 (SD 4) units; P = 0.001 and 6 (SD 7) vs 5 (SD 5) units; P = 0.03] were administered to patients operated on with CPB. A postoperative mechanical right ventricular support device was necessary in 50% vs 41% of patients (P = 0.08). The stroke rate was not significantly different (P 0.99). No difference in survival was observed. CONCLUSIONS: Omitting CPB for an LVAD implant in patients on ECLS is safe and results in shorter operating time, less re-exploration for bleeding and fewer blood products. However, no survival benefit is observed.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Ponte Cardiopulmonar/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Humanos , Pontuação de Propensão , Estudos Retrospectivos , Resultado do Tratamento
11.
Artif Organs ; 45(10): 1240-1249, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34152637

RESUMO

Extracorporeal membrane oxygenation (ECMO) is frequently used in many centers around the globe for various indications. However, prognosis is often poor even with all supportive therapies, and in many cases, clinical deterioration is associated with inflammation. Hemoadsorption with CytoSorb is a novel approach to limit the inflammatory response, and the device can be safely and easily installed into ECMO circuits. CytoSorb has been used more than 130.000 times to date, but because randomized controlled trials are largely lacking, there is substantial debate on its use. Here, experts from critical care medicine, cardiology, cardiac surgery, and perfusion technology discuss the pros and cons of this novel therapy and outline the future aspects for its clinical application and research.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Hemofiltração/instrumentação , Absorção Fisico-Química , Oxigenação por Membrana Extracorpórea/efeitos adversos , Hemofiltração/métodos , Humanos , Inflamação
12.
Ann Cardiothorac Surg ; 10(3): 353-363, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34159116

RESUMO

BACKGROUND: The literature on outcomes of patients requiring durable mechanical circulatory support (MCS) after extra-corporeal life support (ECLS) is limited. The aim of this study was to investigate the impact of preoperative ECLS cannulation on postoperative outcome after durable MCS implantation. METHODS: The durable MCS after ECLS registry is a multicenter retrospective study that gathered data on consecutive patients who underwent durable MCS implantation after ECLS between January 2010 and August 2018 in eleven high volume European centers. Patients who underwent the implantation of total artificial heart, pulsatile pumps, or first-generation pumps after ECLS were excluded from the analysis. The remaining patients were divided into two groups; central ECLS group (cECLS) and peripheral ECLS group (pECLS). A 1:1 propensity score analysis was performed to identify two matched groups. The outcome of these two groups was compared. RESULTS: A total of 531 durable MCS after ECLS were implanted during this period. The ECLS cannulation site was peripheral in 87% (n=462) and central in 13% (n=69) of the patients. After excluding pulsatile pumps and total artificial heart patients, a total of 494 patients remained (pECLS =434 patients, cECLS =60 patients). A 1:1 propensity score analysis resulted in 2 matched groups (each 55 patients) with median age of 54 years (48-60 years) in cECLS group and 54 years (43-60 years) in pECLS group. HeartWare HVAD (Medtronic, Minneapolis, MN) was implanted in the majority of the patients (cECLS =71% vs. pECLS =76%, P=0.67). All postoperative morbidities were comparable between the groups. The thirty-day, one year and long-term survival was comparable between the groups (P=0.73). CONCLUSIONS: The cannulation strategy of ECLS appears to have no impact on the post-operative outcome after durable MCS implantation.

13.
Ann Cardiothorac Surg ; 10(2): 240-247, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33842218

RESUMO

BACKGROUND: Metabolomic profiling has important diagnostic and prognostic value in heart failure (HF). We investigated whether left ventricular assist device (LVAD) support has an impact on the metabolomic profile of chronic HF patients and if specific metabolic patterns are associated with the development of adverse events. METHODS: We applied untargeted metabolomics to detect and analyze molecules such as amino acids, sugars, fatty acids and other metabolites in plasma samples collected from thirty-three patients implanted with a continuous-flow LVAD. Data were analyzed at baseline, i.e., before implantation of the LVAD, and at long-term follow-up. RESULTS: Our results reveal significant changes in the metabolomic profile after LVAD implant compared to baseline. In detail, we observed a pre-implant reduction in amino acid metabolism (aminoacyl-tRNA biosynthesis) and increased galactose metabolism, which reversed over the course of support [median follow-up 187 days (63-334 days)]. These changes were associated with improved patient functional capacity driven by LVAD therapy, according to NYHA functional classification of HF (NYHA class I-II: pre-implant =0% of the patients; post-implant =97% of the patients; P<0.001). Moreover, patients who developed adverse thromboembolic events (n=4, 13%) showed a pre-operative metabolomic fingerprint mainly associated with alterations of fatty acid biosynthesis and mitochondrial beta-oxidation of short-chain saturated fatty acids. CONCLUSIONS: Our data provide preliminary evidence that LVAD therapy is associated with changes in the metabolomic profile of HF and suggest the potential use of metabolomics as a new tool to stratify LVAD patients in regard to the risk of adverse events.

14.
J Card Surg ; 36(4): 1344-1351, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33547707

RESUMO

BACKGROUND: The aim of this study was to evaluate the impact of the surgical approach on the postoperative outcome in patients who underwent left ventricular assist device (LVAD) implantation after having received veno-arterial extracorporeal life support (va-ECLS) using data from a European registry (ECLS-VAD). Five hundred and thirty-one patients were included. METHODS: A propensity score-adjusted outcome analysis was performed, resulting in 324 patients in the full sternotomy (FS) group and 39 in the less invasive surgery (LIS) group. RESULTS: The surgery lasted in median 236 min in the FS group versus 263 min in the LIS group (p = 0.289). The median chest tube output during the first 24 h was similar in both groups. Patients who underwent implantation with an FS required more blood products during the first 24 postoperative hours (median 16 vs. 12, p = 0.033). The incidence of revision due to bleeding was also higher (35.5 vs. 15.4%, p = 0.016). A temporary postoperative right ventricular assist device was necessary in 45.1 (FS) versus 23.1% (LIS) of patients, respectively (p = 0.067). No stroke occurred in the LIS group during the first 30 days after surgery (7.4% in the FS group). The incidence of stroke and of renal, hepatic, and respiratory failure during the follow-up was similar in both groups. The 30-day and one-year survival were similar in both groups. CONCLUSION: LIS for implantation of a durable LVAD in patients on va-ECLS implanted for cardiogenic shock is associated with less revision due to bleeding, less administration of blood products and absence of perioperative stroke, with no impact on survival.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Insuficiência Cardíaca/cirurgia , Humanos , Implantação de Prótese , Estudos Retrospectivos , Resultado do Tratamento
15.
ESC Heart Fail ; 8(1): 167-170, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33161652

RESUMO

We describe the case of a 58-year-old man presenting with myocardial infarction complicated by cardiogenic shock, treated with Impella CP which was escalated to an axillary 5.0 due to lack of cardiac recovery. Weaning from Impella 5.0 failed, and the patient was evaluated for heart transplantation (HTx) or left ventricular assist device (LVAD). HTx was excluded because of a rectal adenocarcinoma. The patient underwent colorectal surgery while on Impella. Perioperative course was uneventful. After 61 days of Impella, when the LVAD implantation was scheduled, the patient died due to K. pneumoniae infection.


Assuntos
Transplante de Coração , Coração Auxiliar , Infarto do Miocárdio , Humanos , Masculino , Pessoa de Meia-Idade , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Resultado do Tratamento
16.
J Am Coll Cardiol ; 76(25): 2956-2964, 2020 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-33334424

RESUMO

BACKGROUND: The decision to implant durable mechanical circulatory systems (MCSs) in patients on extracorporeal life support (ECLS) is challenging due to expected poor outcomes in these patients. OBJECTIVES: The aim of this study was to identify outcome predictors that may facilitate future patient selection and decision making. METHODS: The Durable MCS after ECLS registry is a multicenter retrospective study that gathered data on consecutive patients who underwent MCS implantation after ECLS between January 2010 and August 2018 in 11 high-volume European centers. Several perioperative parameters were collected. The primary endpoint was survival at 1 year after durable MCS implantation. RESULTS: A total of 531 durable MCSs after ECLS were implanted during this period. The average patient age was 53 ± 12 years old. ECLS cannulation was peripheral in 87% of patients and 33% of the patients had history of cardiopulmonary resuscitation before ECLS implantation. The 30-day, 1-year, and 3-year actuarial survival rates were 77%, 53%, and 43%, respectively. The following predictors for 1-year outcome have been observed: age, female sex, lactate value, Model of End-Stage Liver Disease XI score, history of atrial fibrillation, redo surgery, and body mass index >30 kg/m2. On the basis of this data, a risk score and an app to estimate 1-year mortality was created. CONCLUSIONS: The outcome in patients receiving durable MCS after ECLS remains limited, yet preoperative factors may allow differentiating futile patients from those with significant survival benefit.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar/estatística & dados numéricos , Reanimação Cardiopulmonar/métodos , Tomada de Decisão Clínica/métodos , Europa (Continente)/epidemiologia , Oxigenação por Membrana Extracorpórea/instrumentação , Oxigenação por Membrana Extracorpórea/métodos , Oxigenação por Membrana Extracorpórea/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade , Seleção de Pacientes , Prognóstico , Sistema de Registros/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Choque Cardiogênico/fisiopatologia , Choque Cardiogênico/terapia , Taxa de Sobrevida
17.
Eur J Cardiothorac Surg ; 58(2): 328-334, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32298423

RESUMO

OBJECTIVES: After mitral repair for degenerative mitral regurgitation (MR), no or mild (≤1+/4+) residual MR should remain. Occasionally patients are left with more than mild residual MR (>1+/4+) for a number of reasons. The aim of this study was to assess the late implications of such a suboptimal repair in a matched cohort study. METHODS: From 2006 to 2013, a total of 2158 patients underwent mitral repair for degenerative MR in our institution. Fifty patients (2.3%) with residual MR >1+ at hospital discharge (study group) were matched up to 1:2 with 91 patients operated on during the same period who were discharged with MR ≤1+ (control group). The median follow-up was 8 years (interquartile range 6.3-10.1, longest 12.7 years). A comparative analysis of the outcomes in the 2 groups was performed. RESULTS: Overall survival at 8 years was 87 ± 8% in the study group and 92 ± 3% in the control group (P = 0.23). There were 3 late deaths (6.0%) in the study group and 6 deaths (6.6%) in the control group. Freedom from reoperation was similar (P = 1.0). At 8 years the prevalence of MR ≥3+ was significantly higher in the study group (15.6% vs 2.1%, P < 0.001) as was the use of diuretics, beta-blockers and angiotensin-converting enzyme inhibitors/angiotensin-receptor blockers. Interestingly, even in the control group, a gradual progression of MR was observed because 13.3% of the patients had MR ≥2+ at 8 years with a significant increase over time (P < 0.001). CONCLUSIONS: Residual MR more than mild at hospital discharge is associated with lower durability of mitral repair and the need for more medical therapy in the long term. However, even an initial optimal result does not completely arrest the progression of the degenerative process.


Assuntos
Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Estudos de Coortes , Seguimentos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Recidiva , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
18.
J Cardiothorac Vasc Anesth ; 34(1): 119-127, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31445833

RESUMO

OBJECTIVES: Postoperative hemorrhage in cardiac surgery is a significant cause of morbidity and mortality. Standard laboratory tests fail as predictors for bleeding in the surgical setting. The use of viscoelastic (VE) hemostatic assays thromboelastography (TEG) and rotational thromboelastometry (ROTEM) could be an advantage in patients undergoing cardiac surgery. The objective of this meta-analysis was to analyze the effects (benefits and harms) of VE-guided transfusion practice in cardiac surgery patients. DESIGN: A meta-analysis of randomized trials. SETTING: For this study, PubMed, EMBASE, Scopus, and the Cochrane Collaboration database were searched, and only randomized controlled trials were included. A systematic review and meta-analysis were performed in accordance with the standards set forth by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement, using a random-effects model. PARTICIPANTS: The study comprised adult cardiac surgery patients. INTERVENTIONS: VE-hemostatic assays transfusion algorithm compared with transfusion algorithms based on clinicians' discretion. MEASUREMENTS AND MAIN RESULTS: Seven comparative randomized controlled trials were considered, including a total of 1,035 patients (522 patients in whom a TEG- or ROTEM-based transfusion algorithm was used). In patients treated according to VE-guided algorithms, red blood cell (odds ratio 0.61; 95% confidence interval [CI]: 0.37-0.99; p: 0.04; I2: 66%) and fresh frozen plasma transfusions (risk difference 0.22; 95% CI: 0.11-0.33; p < 0.0001; I2: 79%) use was reduced; platelets transfusion was not reduced (odds ratio 0.61; 95% CI: 0.32-1.15; p: 0.12; I2 74%). CONCLUSIONS: This study demonstrated that the use of VE assays in cardiac surgical patients is effective in reducing allogenic blood products exposure, postoperative bleeding at 12 and 24 hours after surgery, and the need for redo surgery unrelated to surgical bleeding.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Tromboelastografia , Adulto , Perda Sanguínea Cirúrgica , Transfusão de Sangue , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Hemostasia , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto
20.
J Invasive Cardiol ; 31(9): E274-E276, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31478896

RESUMO

Three-dimensional multiplanar reconstruction was used to diagnose recurrence of mitral regurgitation after MitraClip implantation in a 71-year-old man. Subsequent mitral valve surgery in such a case is high risk, and repeat MitraClip intervention could be feasible but is technically challenging. This imaging series demonstrates that LVAD implantation may be a solution to address MitraClip failure.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Coração Auxiliar , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA